The DICENTIS system uses its Dynamic Channel Allocation (DCA) technology to sense all
microphones continuously in order to:
–
Quickly open the microphones if audio is detected to prevent missing syllables.
–
Reduce the number of open microphones to prevent noise for optimum speech
intelligibility.
The DCA algorithm keeps the microphone open for 2 seconds for optimum performance.
Due to its continuous sensing of the audio, it can happen that one microphone is shown in the
speaker list even though nobody is speaking.
–
Once you have checked the
Show active microphone
box, you can:
- Use the
Attack time
slider to set the minimal audio duration. The minimal audio
duration prevents short audio spikes, like coughing, from placing the participant in
the speaker list. The attack time sets how long the audio needs to be before it is
regarded as speech. The default recommended is 2000 ms. The minimum is 0 ms.
The maximum is 10 000 ms.
- Use the
Release time
slider to set the duration the microphone stays on after the
audio level becomes too low. The default is 500 ms. The minimum is 0 ms. The
maximum is 10 000 ms.
- Check the
Show active by red mic LED
checkbox to light up the red microphone
LED when the participant is in the speaker list.
- Configure the number of speakers displayed in the speaker list in
Max active
microphones
. One is the recommended value.
–
Speakers list:
–
Max active microphones
: The maximum number of active microphones in the
speakers list can be pre‑selected (max. 25). Disabled when
Voice mode
or
Response
is used.
–
Allow speaker to mute mic
: When selected (default), the participant can use the left
microphone button to temporarily mute the microphone. If disabled, the left
microphone button behaves the same as the right microphone button.
–
Allow speaker to switch mic off
: When selected, participants are allowed to switch
off their microphone. Disabled when
Open (automatic)
,
First in first out
or
Voice
mode
is used.
–
Switch mic off after 30 sec of silence
: This function can be used when participants
forget to switch‑off the microphone manually. Disabled when
Voice mode
or
Response
is used.
–
Ambient microphone
: When selected, the ambient microphone connected to input 1
is enabled.
–
Speakers queue size
:
The maximum number of requests in the waiting list. A
maximum of 200 requests can be selected. Disabled when
First in first out
or
Voice
mode
is used.
–
Allow request to speak
: When selected, request‑to‑speak is allowed. Disabled when
Open (automatic)
,
First in first out
or
Voice mode
is used.
–
Allow cancel request to speak
: When selected, participants are allowed to cancel
their request‑to‑speak. Disabled when
Open (automatic)
,
First in first out
or
Voice
mode
is used.
–
Responders queue size
: The maximum number or requests in the response queue. A
maximum of 99 can be selected. Only available if
Response mode
is used.
–
Allow cancel request-to-respond
. When selected, participants are allowed to cancel
their request-to-respond. Only available if
Response mode
is used.