64
en | Meeting application
DICENTIS
2021.06 | V3.7 |
Configuration manual
Bosch Security Systems B.V.
–
Participant’s device GUI language:
Use the drop-down list to select the required GUI
language of all devices with a graphical user interface. This setting is overruled by the GUI
language setting in the
Persons
page.
–
ScreenLine definition:
The screen line is defined here. To activate the screen line, click
the
Apply
button. The information entered in the general fields of a Person or User (i.e.:
FirstName, LastName, MiddleName, Title, Region, Country) can be inserted here by using
the $‑sign directly in front of the description.
Screenline definition example
: $FirstName $LastName $MiddleName $Title $Region
$Country
Optionally the number of characters of an item shown can be limited from 1 to 99 by adding
the number behind the field between parentheses. Numbers used below 1 or above 99 are
parsed as normal text. The screen line entry must contain at least one of the above items. If
the entry is not accepted, it is enclosed within a red box.
–
Meeting notes location:
The location of the meeting notes is defined here. By default, the
meeting notes are saved on the Server PC in:
\ProgramData\Bosch\DICENTIS
.
Use the
Browse
button to select another location, if required. For more information on
the meeting notes, refer to Post-meeting tools.
Note:
The default location for the meeting notes is only displayed if the DCNM‑LMPM
license is activated.
–
Power off devices when system is idle for:
This function is intended to automatically
turn off the participant devices and interpreter desks when the system is idle for a certain
amount of time to save energy and increase the lifetime of the equipment.
Note:
The system is regarded as being in idle state when the speakers list (or queue) is empty
and when no microphone of a DICENTIS interpreter desk is active. This mode is disabled when
microphone mode
Voice
is used.
The system automatically turns off after 2 hours of inactivity, and this option can be
configured from
Disabled
to
16 hours
.
Note:
This option turns off the system by disabling the 48 V on the high power outputs of the
DICENTIS (Audio processor and) Powering switch.
i
Notice!
Discussion devices and interpreter desks connected to PoE switches will not power off.
The participant devices and interpreter desks can be powered on using the available methods:
–
The power on functionality on the Meeting Application.
–
The power on functionality on the Synoptic Control.
–
The power on functionality on the multimedia device connected to the low power/
always powered DICENTIS output of the DCNM-APS2/DCNM-PS2 (or DCNM-APS/
DCNM-PS).
–
Making a physical power on button based on the circuit-diagram described in
chapter 5.5.5 of the DICENTIS Installation manual.
This function is enabled by default on new systems and after upgrading the system software
to the 3.2 version.