Multi-Tiered Storage
106
Titan SiliconServer
unreliable disks promptly, thus preventing the RAID controller from failing them at a critical
time.
Media Scan can detect drive media errors before they are found during a normal read or write to
the System Drive. The Media Scan operation is performed as a background task and scans all
data and parity information on the configured system drives. It will run on all System Drives
that are
optimal
(meaning are operating without known failures) and have no modification
operations in progress. Errors detected during a media scan will be reported to the Event Log.
Media scan runs at a lower priority on the RAID controller than normal storage access. However,
performance can be maximized by increasing the time allowed for the media scan to complete.
To increase the duration of the media scan and, as a result reduce the cycles used by the RAID
controller, the
Media Scan Period
can be increased to up to 30 days on the
RAID Rack Details
page.
Checking the Status of Active Tasks
You can view the status of on-going activity (Media Scan, CopyBack, initializing, etc.) within the
RAID Rack on the
Active Tasks
page.
1.
From the
Home
page, click
Storage Management
. Then, click
RAID Racks
.
2.
Check the check box next to the RAID Rack on which to view the Active Tasks.