MERCURY PLUS
1-31
1.8.2 Table of electrical values
Power supply:
240 +10%-15% Vac 50/60 Hz
Load cells that can be connected: up to 4 350 Ohm analog cells on
the 9-pin connector
Analog load cell power:
10 Vdc
Resolution:
up to 10000 divisions
Maximum input signal:
23 mV
Sensitivity:
0.75 uV/division (version with
analog cells)
Full scale stability:
< 5 ppm/°C
Zero stability:
< 5 ppm/°C
Compensated temperature range: 0 + 40 °C
Operating range:
0 + 50 °C
Humidity:
85 % @ 40°C
Table 1.1 - Electrical values
Version
Panel
On top
printing
unit
Underneath
printing
unit
Optional
CGM
Totalizer
3 belts
500VA
170VA
170VA
170VA
4 belts
500VA
170VA
170VA
170VA
Table 1.2 - Power input
Содержание Cigiemme MERCURY PLUS
Страница 1: ...MERCURY PLUS Instruction manual Code 81320114 EDITION 02 05 2016 January 2007 ...
Страница 2: ......
Страница 12: ...MERCURY PLUS 1 12 ...
Страница 19: ...1 19 MERCURY PLUS 1 4 10 Glossary Gives the meanings of the technical terms used in this manual ...
Страница 62: ...MERCURY PLUS 1 62 ...
Страница 94: ...MERCURY PLUS 1 94 5 9 List of menus Figure 5 2 1 3 menu list citi6117 en jpg ...
Страница 95: ...MERCURY PLUS 1 95 Figure 5 3 2 3 menu list citi6118 en jpg ...
Страница 96: ...MERCURY PLUS 1 96 Figure 5 4 3 3 menu list citi6119 en jpg ...
Страница 194: ...MERCURY PLUS 1 194 ...
Страница 196: ...MERCURY PLUS 1 196 Figure 6 1 Permit combinations citi6134 jpg ...
Страница 234: ...MERCURY PLUS 1 234 ...
Страница 250: ...MERCURY PLUS 1 250 ...
Страница 259: ......