MERCURY PLUS
1-186
5.22.11 Output table
Logic output
Pin N°
Function
NOTES
OUT-1
J10-PIN3_4
Enabling by prior
machine
OUT-2
J12-PIN1_2
Spare
With relay
OUT-3
J10-PIN6_7
Fault/Block
Activated relay output when
the machine is blocked for
one of the following faults,
which will appear on the
screen:
✔
Emergency
✔
No compressed air
✔
No more paper
✔
Applicator error
✔
Positioning errors
✔
And other blocking
errors that force the
machine to quit the
process
✔
Red light
OUT-4
J12-PIN4_5
Spare
With relay
OUT-5
J10-PIN8_9
Line running/Line
at a standstill
Activated relay output when
the machine is operating
and the belts may start
automatically at any time,
even without the operator's
intervention.
Output deactivated when
the machine is at a
standstill, the belts are
stopped and cannot restart
without a command from the
operator.
CONVEYOR BELT function
enabled. The output is
activated.
Green light
OUT-6
J12-PIN7_8
Spare
With relay
OUT-7
J12-PIN9_10
Spare
With relay
OUT-8
J11-PIN1_2
Tot. 2 label in
queue
With relay
OUT-9
J2-PIN9
Assist Blow
Содержание Cigiemme MERCURY PLUS
Страница 1: ...MERCURY PLUS Instruction manual Code 81320114 EDITION 02 05 2016 January 2007 ...
Страница 2: ......
Страница 12: ...MERCURY PLUS 1 12 ...
Страница 19: ...1 19 MERCURY PLUS 1 4 10 Glossary Gives the meanings of the technical terms used in this manual ...
Страница 62: ...MERCURY PLUS 1 62 ...
Страница 94: ...MERCURY PLUS 1 94 5 9 List of menus Figure 5 2 1 3 menu list citi6117 en jpg ...
Страница 95: ...MERCURY PLUS 1 95 Figure 5 3 2 3 menu list citi6118 en jpg ...
Страница 96: ...MERCURY PLUS 1 96 Figure 5 4 3 3 menu list citi6119 en jpg ...
Страница 194: ...MERCURY PLUS 1 194 ...
Страница 196: ...MERCURY PLUS 1 196 Figure 6 1 Permit combinations citi6134 jpg ...
Страница 234: ...MERCURY PLUS 1 234 ...
Страница 250: ...MERCURY PLUS 1 250 ...
Страница 259: ......