Page 35
Parameter
Functional description
Setting range
Factory values
Customer
values
Arctis/
Duplex
Vulcano Cold
Rack/
Showca
ses
F54
Condenser fan switching hysteresis.
0.1...15.0 °C
10.0
10.0
10.0
F58
Condenser fan, delay after compressor
start.
0...300 s
60.0
60.0
60.0
F59
Condenser fan, delay after compressor
stop (run-on).
0...600 s
300
300
300
F65
Condenser fan function.
0: Always off
1: Always on
2: On when compressor on
3: According to setpoint
F51
4: As 3, as P-controller
2
2
2
F66
P-controller proportional range with
F65
= 4
0.1 ... 30.0 °C
10.0
10.0
10.0
F67
Minimum speed (output PWM with
result = 0).
0 ... 100 %
50.0
50.0
50.0
F68
Condenser fan start boost.
0 ... 60 s
10
10
10
F99
Password for parameter level
F--
- 99 ... 999
0
0
0
H--
Temperature probes and sensors
Parameter
Functional description
Setting range
Factory values
Customer
values
Arctis/
Duplex
Vulcano Cold
Rack/
Showca
ses
H1
Mains frequency.
0: 50 Hz
1: 60 Hz
0
0
0
H11
Sensor F1 actual value.
Measured value, not adjustable
H12
Sensor F1 calibration (actual value
correction).
- 20...+ 20.0 °C
0.0
0
0
H13
Sensor F1 weighting factor.
0.50...1.50
1.00
1.00
1.00
H14
Sensor F1 sensor selection. Not all
types are available depending on the
hardware. In this case, the sensor is
deactivated.
0: Not available
1: PTC
(-
50…..+ 150 °C)
2: Pt100, 2-wire (-
100…+ 600 °C)
3: Pt100, 3-wire (-
100…+ 500 °C)
4: NTC
( -
40……+ 40 °C)
5: Pt1000, 2-wire (-
100…+ 330 °C)
6: Pt1000, 3-wire (-
100…+ 300 °C)
7: 0-20 mA
8: 4-20 mA
1
1
1
H15
Sensor F1 software filter.
1 .. 32
8
8
8
H16
Display at 0/4 mA and sensor selection
H14
= 7/8
- 99..+ 999
0.0
0.0
0.0
H17
Display at 20 mA and sensor selection
H14
= 7/8
- 99..+999
100
100
100
H21
Sensor F2 actual value.
Measured value, not adjustable
H22
Sensor F2 calibration (actual value
correction).
- 20...+ 20.0 °C
0.0
0.0
0.0
H23
Sensor F2 weighting factor.
0.50...1.50
1.00
1.00
1.00
H24
Sensor F2 sensor selection.
See
H14
1
1
1
H25
Sensor F2 software filter.
1 .. 32
8
8
8
H26
Display at 0/4 mA and sensor selection
H24
= 7/8
- 99..+ 999
0.0
0.0
0.0
H27
Display at 20 mA and sensor selection
H24
= 7/8
- 99..+999
100
100
100