N-level (counter)
Parameter can only be accessed via the ST bus.
Parameter
Function
Setting range
Standard
Customer
values
Arctis/
Duplex
Vulcano Cold
Rack/
Showca
ses
N0
Switching cycles of relay K1 (lower 16 bits).
-
N1
Switching cycles of relay K1 (upper 16 bits).
-
N2
Switching cycles of relay K2 (lower 16 bits).
-
N3
Switching cycles of relay K2 (upper 16 bits).
-
N4
Switching cycles of relay K3 (lower 16 bits).
-
N5
Switching cycles of relay K3 (upper 16 bits).
-
N6
Switching cycles of relay K4 (lower 16 bits).
-
N7
Switching cycles of relay K4 (upper 16 bits).
-
N8
Switching cycles of relay K5 (lower 16 bits).
--
N9
Switching cycles of relay K5 (upper 16 bits).
N10
Switching cycles of relay K6 (lower 16 bits).
-
N11
Switching cycles of relay K6 (upper 16 bits).
-
N12
Switching cycles of relay K7 (lower 16 bits).
-
N13
Switching cycles of relay K7 (upper 16 bits).
-
N14
Switching cycles of relay K8 (lower 16 bits).
-
N15
Switching cycles of relay K8 (upper 16 bits).
-
N98
Reset counter.
0: -
1: Reset
0
0
0
N99
Password for N-level.
-
99 … 999
0
0
0
The number of switching cycles for K1, for example, is calculated as follows:
Number =
65536 * N1 + N0
.
Parameter N98 resets all relay switching cycle counters. It depends on the setting in parameter L42. The return value is automatically
set back to 0.