Control loop 2
(password-protected)
Y0
Sensor assignment for an independent 2nd control loop (thermostat)
This parameter is used to set which sensor input is to be assigned to the 2nd control loop.
Y1
Control loop 2: Setpoint
The setpoint for the 2nd control loop (thermostat) is set here. If a key is parametrised accordingly, the setpoint can also be
displayed and set directly by the key.
Y2
Control loop 2: Absolute or DeltaW setpoint
The value in
Y1
is used in the setting
Y2 = 0
as the absolute setpoint or, with
Y2
= 1, as the sum of
Y1
and the current
cooling space setpoint
(c1
,
c2
or
c3
) for controlling control loop 2.
Y4
Control loop 2: Switching direction
Heating contact or cooling contact.
Y5
Control loop 2: Hysteresis
This parameter specifies the control hysteresis. A small hysteresis allows more precise control, but also leads to more
frequent switching of the relay.
Y6
Control loop 2: Hysteresis mode
This parameter can be used to select if the hysteresis at the respective switching point is symmetrical or takes effect on one
side. A hysteresis programmed on one side is applied below the setpoint for the heating function [
Y4 = 0
] and above it for
the cooling function [
Y4 = 1
]. If the hysteresis is symmetrical, there is no difference.
Y7
Control loop 2: Setpoint limit, top
Y8
Control loop 2: Setpoint limit, bottom
These parameters limit the setting range of the
Y1
setpoint so that the end user does not set any invalid values.
Y9
Control loop 2: Function in the event of a sensor fault
This specifies if the controlled output contact opens or closes in the event of a fault in the assigned sensor.
Y10
Control loop 2: Defrost interval
The defrosting interval determines the time after which defrosting is initiated. At the start of defrosting, the defrosting interval
is restarted, resulting in periodic defrosting with a fixed time interval.
Y11
Control loop 2: Defrost time limit
This sets the maximum time available for defrosting.
Y99
Password for parameter level
Y--
This parameter is used to set the password for parameter level
Y--
.