3.4 Technical data for display:
Ver. 1.11
Displays
Three-digit LED display, 13 mm high, pure white
Five LEDs, diameter 3 mm, white, to indicate status
Power supply
12 V =, provided by the controller
Connections
RJ45 for CAT5 cable (4 x twisted pair)
ATTENTION:
Do not use for ETHERNET!
Environmental
conditions
Storage temperature
-20...+ 70 °C
Operating temperature
0...55 °C
Relative humidity
max. 75 % r.H., no condensation
Degree of protection
IP65 from the front, IP00 from behind
Protection class
Protection class III (appliance carries low voltage only)
Standards
CE Low Voltage Directive 73/23/EEC
EN 60335-1:2009 Safety of household and similar electrical appliances
EN 60730-1:2012 Automatic electrical controls for household and similar use
EN 61010-1:2002 Safety requirements for electrical equipment for
measurement, control and laboratory use
CE EMC Directive 2004/108/EC, Severity 3
Interface
ST bus for connection to a controller
ST bus with RS485 interface driver, not electrically isolated, 56 kbaud,
maximum cable length 1000 m, bus termination switchable
Installation details
The appliance is designed for installation in a control panel
External dimensions
125 x 60 mm
Control panel cutout
102.2 x 52.5 mm, see drawing
Installation depth:
22 mm (excluding mating connector)