9440300990 Rev J
75
DECS-250
Metering
Var/PF Mode:
Three indicators report whether Var mode, Power Factor mode, or neither mode is active.
When a mode is active, its corresponding indicator changes from gray to green. When neither mode is
active, the Off indicator changes from gray to green. Var mode is enabled by clicking the
var
button and
Power Factor mode is enabled by clicking the
PF
button. Neither mode is enabled by clicking the
Off
button. Only one mode can be enabled at any time.
Setpoint Pre-position:
A control button and indicator is provided for the three setpoint pre-positions.
Clicking the
Set 1
button adjusts the excitation setpoint to the Pre-position 1 value and changes the Pre-
position 1 indicator to green. Pre-positions 2 and 3 are selected by clicking either the Set 2 or Set 3
button.
Setpoints:
Five status fields display the active setpoints for AVR mode, FCR mode, FVR mode, var
mode, and Power Factor mode. These active setpoints, represented by a yellow font, are not to be
confused with metered analog values which are represented by a green font throughout BESTCOMS
Plus
.
For details on operating setpoint settings, see the
Regulation
chapter.
Setpoint Fine Adjust:
Clicking the
Raise
button increases the active operating setpoint. Clicking the
Lower
button decreases the active operating setpoint. The raise and lower increment is directly
proportional to the adjustment range and inversely proportional to the traverse rate.
Alarm Status
: The Alarm Status indicator changes from gray to green when there is an active alarm.
PSS Status
: The PSS Status indicator changes from gray to green when the PSS is active.
Null Balance
: The Null Balance indicator changes from gray to green when the setpoint of the inactive
operating modes (AVR, FCR, FVR, var, and PF) match the setpoint of the active mode.
Virtual Switches
: These buttons control the open or closed status of the six virtual switches. Clicking the
Open button sets the switch to the open position and changes the switch indicator to gray. Clicking the
Close button sets the switch to the closed position and changes the switch indicator to red. A dialog will
appear asking if you are sure you want to open or close the switch.
Metering Summary
BESTCOMSPlus Navigation Path:
Metering Explorer, Summary
HMI Navigation Path:
Not available via HMI
All of the metering values displayed on the individual, previously-described metering screens are
consolidated on the metering summary screen. Primary- and per-unit values are available. Figure 68
illustrates the primary-values metering summary screen. The primary- and per-unit metering summary
screens are available only in BESTCOMS
Plus
.
Содержание DECS-250
Страница 2: ......
Страница 6: ...iv 9440300990 Rev J Revision History DECS 250 ...
Страница 16: ...xiv 9440300990 Rev J Contents DECS 250 ...
Страница 20: ...4 9440300990 Rev J Introduction DECS 250 ...
Страница 28: ...12 9440300990 Rev J Power Stage DECS 250 ...
Страница 32: ...16 9440300990 Rev J Voltage and Current Sensing DECS 250 ...
Страница 40: ...24 9440300990 Rev J Synchronizer DECS 250 ...
Страница 52: ...36 9440300990 Rev J Auxiliary Control DECS 250 ...
Страница 56: ...40 9440300990 Rev J Contact Inputs and Outputs DECS 250 ...
Страница 84: ...68 9440300990 Rev J Limiters DECS 250 ...
Страница 108: ...92 9440300990 Rev J Power System Stabilizer DECS 250 Figure 85 PSS Function Blocks and Software Switches ...
Страница 114: ...98 9440300990 Rev J Power System Stabilizer DECS 250 Figure 96 PSS Parameter Settings ...
Страница 124: ...108 9440300990 Rev J Stability Tuning DECS 250 ...
Страница 126: ...110 9440300990 Rev J Mounting DECS 250 Figure 103 Overall and Projection Mounting Dimensions ...
Страница 127: ...9440300990 Rev J 111 DECS 250 Mounting Figure 104 DECS 250 Escutcheon Plate Dimensions ...
Страница 128: ...112 9440300990 Rev J Mounting DECS 250 Figure 105 Panel Cutting and Drilling Dimensions for DECS 250 Panel Mounting ...
Страница 198: ...182 9440300990 Rev J Timekeeping DECS 250 ...
Страница 210: ...194 9440300990 Rev J CAN Communication DECS 250 ...
Страница 304: ...288 9440300990 Rev J Maintenance DECS 250 ...
Страница 316: ...300 9440300990 Rev J Specifications DECS 250 ...
Страница 334: ...318 9440300990 Rev J Analog Expansion Module DECS 250 ...
Страница 341: ...9440300990 Rev J 325 DECS 250 Contact Expansion Module Figure 188 CEM 2020 Input Contact and Output Contact Terminals ...
Страница 351: ......