Command
Group
Item
Description
Set
Ethernet
Gateway
Set new Gateway IP address. A 'Re-
boot' command is required to be sent
from the command channel to make
the new address effective.
Examples
>>
do system save
\x0D\x0A
<<
OK\x0D\x0A
8.4 Status Command Group
Command
Group
Item
Description
Get
Status
Ready
Flag indicating whether the sys-
tem is ready to trigger (true) or
busy (false)
Get
Status
SystemError
Flag indicating whether a sys-
tem error is active (true) or
cleared (false)
Do
Status
ClearSystemError
Clears the system error LED
and sets the internal flag to
false.
Examples
>>
get status ready
\x0D\x0A
<<
OK\x0D\x0A
<<
True\x0D\x0A
>>
get status systemerror
\x0D\x0A
<<
OK\x0D\x0A
<<
False\x0D\x0A
>>
do status clearsystemerror
\x0D\x0A
<<
OK\x0D\x0A
8.4 Trigger Command Group
Command
Group
Item
Description
Get
Trigger
Mode
The sensor's triggering mode.
This value must match the
modes supported by the sensor.
This value can be modified us-
ing the sensor's touchscreen.
This remotely modified value is
not persisted to the sensors per-
manent memory. The 'Save' op-
iVu Plus BCR User's Manual
Rev. B
www.bannerengineering.com - tel: 763-544-3164
89
Содержание iVu Plus BCR
Страница 1: ...iVu Plus BCR User s Manual Rev B 1 25 2012...
Страница 56: ...iVu Plus BCR User s Manual 56 www bannerengineering com tel 763 544 3164 Rev B...
Страница 58: ...Main Menu Imager Exposure iVu Plus BCR User s Manual 58 www bannerengineering com tel 763 544 3164 Rev B...
Страница 64: ...iVu Plus BCR User s Manual 64 www bannerengineering com tel 763 544 3164 Rev B...
Страница 104: ...iVu Plus BCR User s Manual 104 www bannerengineering com tel 763 544 3164 Rev B...
Страница 105: ...2 Select Module iVu Plus BCR User s Manual Rev B www bannerengineering com tel 763 544 3164 105...
Страница 155: ...T Touchscreen Calibration 34 U USB loading from 24 saving to 24 Rev B www bannerengineering com tel 763 544 3164 155...