Image Export Channel
Main Menu > System > Communications > Image Export
When the Image Export Channel is enabled, the sensor will transmit the acquired image on every trigger. The image is transmitted as a
bitmap (BMP) file. This operation is only available over Ethernet I/O.
3.2.6 Discrete I/O
The Discrete I/O options are used to adjust iVu input and output settings.
Main Menu > System > Discrete I/O
Input Polarity
The iVu has two input signals—Trigger and Remote Teach. The operation of these signals is dependent on the Input Polarity setting.
• Low To High - The Trigger and Remote Teach are detected on a low to high transition of the signal.
• High To Low - The Trigger and Remote Teach are detected on a high to low transition of the signal.
The default setting for a PNP sensor is Low To High, and for an NPN sensor it is High To Low. The user can change the setting on the
Input Polarity screen.
Main Menu > System > Discrete I/O > Input Polarity
iVu Plus BCR User's Manual
Rev. B
www.bannerengineering.com - tel: 763-544-3164
31
Содержание iVu Plus BCR
Страница 1: ...iVu Plus BCR User s Manual Rev B 1 25 2012...
Страница 56: ...iVu Plus BCR User s Manual 56 www bannerengineering com tel 763 544 3164 Rev B...
Страница 58: ...Main Menu Imager Exposure iVu Plus BCR User s Manual 58 www bannerengineering com tel 763 544 3164 Rev B...
Страница 64: ...iVu Plus BCR User s Manual 64 www bannerengineering com tel 763 544 3164 Rev B...
Страница 104: ...iVu Plus BCR User s Manual 104 www bannerengineering com tel 763 544 3164 Rev B...
Страница 105: ...2 Select Module iVu Plus BCR User s Manual Rev B www bannerengineering com tel 763 544 3164 105...
Страница 155: ...T Touchscreen Calibration 34 U USB loading from 24 saving to 24 Rev B www bannerengineering com tel 763 544 3164 155...