2.2.3 Compare Data
The iVu Plus BCR has a data compare feature for comparing read barcode data against reference data. Data can be manually entered
by accessing the Main Menu > Inspection > Barcode > Data Compare > Set Data screen. Data of up to 3200 characters can be
entered. Additionally, the data compare feature provides for masking characters within the data.
There are two other ways to enter compare data:
• Importing the last read data while viewing the Set Data screen. The new data is effective on the first trigger that occurs after this
action.
• Using Remote Teach. When a Remote Teach occurs, the data of the first read barcode is saved as Data Compare input. Inspections
executed on the next trigger will use the new data for comparison with subsequently read barcodes. If the previous input data con-
tained any masked characters, Remote Teach will retain the masked characters only if the new data is of the same length as the
previous input data. If the length does not match, masking is removed.
The sensor tries to compare full length of this string with the data read from the barcode. If not equal, inspection will be marked as Fail.
NOTE: If the sensor reads more than one barcode in the field of view, only the first barcode data that the
sensor reads can be compared.
2.2.4 Output 1, Output 2, and Output 3
The sensor has three output signals that you can configure for Pass, Fail, Read, No Read, Match, No Match, System Error, and Missed
Trigger. The default settings are Pass for Output 1, Fail for Output 2, and Pass for Output 3.
NOTE: For all outputs, the default setting is Latched, which means that the signal is active until the results of
an inspection cause a change in the signal output. If Pulsed is selected, the default pulse width is 50 ms.
2.2.5 Serial and Ethernet Output
The iVu Plus provides for communicating with other devices via Ethernet or a UART serial communications port (RS-232 ). In order to
establish an Ethernet connection to the sensor, the external device must be configured with the correct IP address and correct TCP port
to communicate. If planning to use the serial communications connection, port settings for baud rate, data bits, parity, and stop bits must
be configured on the iVu Plus to match the settings of the external device.
iVu Plus BCR User's Manual
18
www.bannerengineering.com - tel: 763-544-3164
Rev. B
Содержание iVu Plus BCR
Страница 1: ...iVu Plus BCR User s Manual Rev B 1 25 2012...
Страница 56: ...iVu Plus BCR User s Manual 56 www bannerengineering com tel 763 544 3164 Rev B...
Страница 58: ...Main Menu Imager Exposure iVu Plus BCR User s Manual 58 www bannerengineering com tel 763 544 3164 Rev B...
Страница 64: ...iVu Plus BCR User s Manual 64 www bannerengineering com tel 763 544 3164 Rev B...
Страница 104: ...iVu Plus BCR User s Manual 104 www bannerengineering com tel 763 544 3164 Rev B...
Страница 105: ...2 Select Module iVu Plus BCR User s Manual Rev B www bannerengineering com tel 763 544 3164 105...
Страница 155: ...T Touchscreen Calibration 34 U USB loading from 24 saving to 24 Rev B www bannerengineering com tel 763 544 3164 155...