Industrial Ethernet Only
When Industrial Ethernet communication channel is enabled, triggers can be received from the modes mentioned above. Triggers
through Industrial Ethernet will not be executed if selected Trigger Mode is 'Continuous Scan'. If it is desired to receive triggers only
through Industrial Ethernet channel, select the 'Industrial Ethernet Only'.
3.3.5 Focus
The Focus Number displayed at the bottom of this screen is used to fine-tune image focus. Loosen the lock on the lens cover, turn the
focus ring on the sensor until the Focus Number peaks (or the image appears sharp), then lock the focus ring.
NOTE: For the Focus Number to work, the sensor must be triggering and the images must be similar over
time.
Main Menu > Imager > Focus
iVu Plus BCR User's Manual
Rev. B
www.bannerengineering.com - tel: 763-544-3164
39