Input Commands
The following commands need to be executed using Command ID and the Command Bit stated above.
Command
Command ID
Description
Data Type
Do
Set
Get
Trigger
Trigger Mode
1
10001 The sensor's triggering mode. This value must match the
modes supported by the sensor
Int16
Product Change
Product Change By
Name
21
This command forces the sensor to switch to the specified in-
spection. The sensor does not transmit a response until the
sensor has completed the action. Inspections results immedi-
ately after a product change will be invalid until a new trigger is
received.
Byte Array
Imager
Gain
51
10051 The sensor's value used to electronically brighten all image
pixels
Int32
Exposure
52
10052 The sensor's value used to control the amount of time the im-
ager is allowed to gather light for the image.
Int32
Status
Clear System Error
81
This command clears the system error LED and resets the in-
ternal system error flag to false.
N/A
System
Reboot Sensor
101
This command reboots the sensor. If sensor configuration data
is being currently being saved, this command will block until
that operation completes
N/A
Save Configuration
102
This command saves all modified inspection and configuration
parameters. This command blocks until all values have been
persisted
N/A
Info
Sensor Name
10151 Sensor user assignable name.
Byte Array
Model Number
10152 Sensor model number
Byte Array
Serial Number
10153 Sensor serial number
Byte Array
Firmware Version
10154 Sensor firmware (software) version
Byte Array
Hour Counter
10155 The total number of hours the sensor has been energized.
Byte Array
History
Clear History
301
This command clears all history fields for the active inspection.
History values include pass count, fail count, execution times
and tool specific history values.
N/A
Inspection
Inspection Name
10501 The name of the active inspection.
Byte Array
iVu Plus BCR User's Manual
Rev. B
www.bannerengineering.com - tel: 763-544-3164
101
Содержание iVu Plus BCR
Страница 1: ...iVu Plus BCR User s Manual Rev B 1 25 2012...
Страница 56: ...iVu Plus BCR User s Manual 56 www bannerengineering com tel 763 544 3164 Rev B...
Страница 58: ...Main Menu Imager Exposure iVu Plus BCR User s Manual 58 www bannerengineering com tel 763 544 3164 Rev B...
Страница 64: ...iVu Plus BCR User s Manual 64 www bannerengineering com tel 763 544 3164 Rev B...
Страница 104: ...iVu Plus BCR User s Manual 104 www bannerengineering com tel 763 544 3164 Rev B...
Страница 105: ...2 Select Module iVu Plus BCR User s Manual Rev B www bannerengineering com tel 763 544 3164 105...
Страница 155: ...T Touchscreen Calibration 34 U USB loading from 24 saving to 24 Rev B www bannerengineering com tel 763 544 3164 155...