4. Write. IP Address of the iVu Plus is entered here.
9.6.2 Output Registers
The Input registers are used by the PLC to push values to the iVu Plus sensor. MSG (message) commands used to Read (N7) and Write
(N14) to the sensor.
Output Registers Map (N14)
WORD #
WORD NAME
DATA TYPE
0
Input Coil Bits
16-bit integer
1-2
Product Change Number
32-bit integer
3-49
reserved
32-bit integer
50
Command
16-bit integer
51
Command Parameter Int16
16-bit integer
52-53
Command Parameter Int 32
32-bit integer
54-55
Command Parameter
Float
56-57
Command Parameter String Length
32-bit integer
58-107
Command Parameter String
100 Byte Array
108
reserved
16-bit integer
109-110
BCR String/Mask Length
32-bit integer
111-120
BCR String/Mask
200 Byte Array
211-239
reserved
iVu Plus BCR User's Manual
134
www.bannerengineering.com - tel: 763-544-3164
Rev. B
Содержание iVu Plus BCR
Страница 1: ...iVu Plus BCR User s Manual Rev B 1 25 2012...
Страница 56: ...iVu Plus BCR User s Manual 56 www bannerengineering com tel 763 544 3164 Rev B...
Страница 58: ...Main Menu Imager Exposure iVu Plus BCR User s Manual 58 www bannerengineering com tel 763 544 3164 Rev B...
Страница 64: ...iVu Plus BCR User s Manual 64 www bannerengineering com tel 763 544 3164 Rev B...
Страница 104: ...iVu Plus BCR User s Manual 104 www bannerengineering com tel 763 544 3164 Rev B...
Страница 105: ...2 Select Module iVu Plus BCR User s Manual Rev B www bannerengineering com tel 763 544 3164 105...
Страница 155: ...T Touchscreen Calibration 34 U USB loading from 24 saving to 24 Rev B www bannerengineering com tel 763 544 3164 155...