Sensor Type - Match (iVu Plus TG)
REGISTER
WORD NAME
DATA TYPE
30001
Coil ACK Bits
16-bit integer
30002
Status Coil Bits
16-bit integer
30003-4
Error Code
32-bit integer
30005-6
Inspection Number
32-bit integer
30007-8
Iteration Count
32-bit integer
30009-10
Pass Count
32-bit integer
30011-12
Fail Count
32-bit integer
30013-14
Missed Triggers
32-bit integer
30015-16
Current Inspection
Time
Float
30017-30
reserved
30031-53
Inspection Name
2-Word Length
+ 40-unicode
chars
30054-55
Frame Number
32-bit integer
REGISTER
WORD NAME
DATA TYPE
30056
Sensor Type ID
16-bit integer
30057-58
Match Count
32-bit integer
30059
Match Min Percent Match
16-bit integer
30060
Match Max Percent Match
16-bit integer
30061-171
reserved
30172
Command Status
32-bit integer
30173
Command Response
Int16
16-bit integer
30174-75
Command Response
Int32
32-bit integer
30176-77
Comand Response
Float
30178-79
Command Response
Length
32-bit integer
30180-229
Command Response Da-
ta
100 Byte Array
30230-240
reserved
iVu Plus BCR User's Manual
128
www.bannerengineering.com - tel: 763-544-3164
Rev. B
Содержание iVu Plus BCR
Страница 1: ...iVu Plus BCR User s Manual Rev B 1 25 2012...
Страница 56: ...iVu Plus BCR User s Manual 56 www bannerengineering com tel 763 544 3164 Rev B...
Страница 58: ...Main Menu Imager Exposure iVu Plus BCR User s Manual 58 www bannerengineering com tel 763 544 3164 Rev B...
Страница 64: ...iVu Plus BCR User s Manual 64 www bannerengineering com tel 763 544 3164 Rev B...
Страница 104: ...iVu Plus BCR User s Manual 104 www bannerengineering com tel 763 544 3164 Rev B...
Страница 105: ...2 Select Module iVu Plus BCR User s Manual Rev B www bannerengineering com tel 763 544 3164 105...
Страница 155: ...T Touchscreen Calibration 34 U USB loading from 24 saving to 24 Rev B www bannerengineering com tel 763 544 3164 155...