Programming guidelines
126
ACOPOSinverter P84 User's Manual 2.10
Other configurations and settings
Only in the "Hoist" macro configurations and "Mast./Slave" are additional parameters assigned outside the I/O
assignment.
Hoisting:
•
[Movement type]
(bSt)
=
[Hoisting]
(UEr)
,
see "[BRAKE LOGIC CONTROL] (bLC-)" on page 223
•
[Brake contact]
(bCI)
=
[No]
(nO)
,
see "[BRAKE LOGIC CONTROL] (bLC-)" on page 223
•
[Start pulse brake]
(bCI)
=
[No]
(nO)
see "[BRAKE LOGIC CONTROL] (bLC-)" on page 223
•
[I Brake release upw.]
(Ibr)
=
[Rated current motor]
(nCr)
,
see "[BRAKE LOGIC CONTROL] (bLC-)" on
•
[Brake release time]
(brt)
= 0.5 s,
see "[BRAKE LOGIC CONTROL] (bLC-)" on page 223
•
[Freq. brake release]
(bIr)
=
[Auto]
(AUtO)
see "[BRAKE LOGIC CONTROL] (bLC-)" on page 223
•
[Freq. brake engage]
(bEn)
=
[Auto]
(AUtO)
see "[BRAKE LOGIC CONTROL] (bLC-)" on page 223
•
[Brake engage time]
(bEt)
see "[BRAKE LOGIC CONTROL] (bLC-)" on page 223
•
[Engage at rev.]
(bEd)
=
[No]
(nO)
see "[BRAKE LOGIC CONTROL] (bLC-)" on page 223
•
[Jump at reversal]
(JdC)
=
[Auto]
(AUtO)
,
see "[BRAKE LOGIC CONTROL] (bLC-)" on page 223
•
[Time to restart]
(ttr)
see "[BRAKE LOGIC CONTROL] (bLC-)" on page 223
•
[Current ramp time]
(brr)
= 0 s,
see "Overview of parameters for the brake logic (brH2 - brr)" on page 226
•
[Low speed]
(LSP)
= Motor slip calculated by inverter,
see "Parameters that can be modified during oper-
ation or when the motor is stopped." on page 130
•
[Output Phase Loss]
(OPL)
=
[Yes]
(YES)
,
see "THERM. MOTOR PROTECTION (tHt) and LOSS OF
MOTOR PHASE (OPL)" on page 292
. No more changes can be made to this parameter.
•
[TRAP WHEN RUNNING]
(FLr)
=
[No]
(nO)
,
see "CATCH ON THE FLY (FLr-)" on page 290
. No more
changes can be made to this parameter.
Mast./Slave:
•
[MOTOR CONTROL TYPE]
(Ctt)
=
[SVC I]
(CUC)
see "Drive parameters (Ctt)" on page 153
Note:
These assignments are forced for each change of the macro configuration, except
[Motor control type]
(Ctt)
for the case of in
[FVC]
(FUC)
Mast./Slave configured macro configuration.
Reset to factory settings:
When resetting to factory settings with the command
[Select config.]
(Source config.)
(FCSI)
=
[Macro conf]
(InI),
,
see "Factory setting parameters (FCS1 - SCS1)" on page 315
the inverter is reset to the selected macro reset con-
figuration. The parameter
[Macro config.]
(CFG)
does not change, however
[Customer spec. macro]
(CCFG)
is
deleted.
Note:
The factory setting displayed in the parameter tables corresponds to
[Macro config.]
(CFG)
=
[Start/
Stop]
(StS)
. This is the factory-set macro configuration
Содержание ACOPOSinverter P84
Страница 2: ......
Страница 384: ...Accessories 384 ACOPOSinverter P84 User s Manual 2 10 8I0FT180 300 1 A Nm lb in 8I0FT180 300 1 25 221 3...
Страница 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Страница 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Страница 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Страница 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Страница 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Страница 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...