Integrated safety functions
352
ACOPOSinverter P84 User's Manual 2.10
STO
f
t
Examples: Vertical conveyor, vertical pulling, lifting or winding equipment.
Fault inhibition
For certain types of errors,
[Fault inhibit assign.]
(InH)
can be requested to prevent the inverter from stopping
when an error occurs. The function of the fault inhibition is not compatible with the behavior of the safety function.
If a safety function is activated, then the fault state generated by the
PrA
safety function cannot be inhibited.
Factory settings
If the inverter is in a safe state and the factory settings are enabled, then only non-safety-related parameters are
downloaded to the inverter. Safety parameters are not affected by the reset to factory settings.