Programming guidelines
128
ACOPOSinverter P84 User's Manual 2.10
Overview of parameters [SIMPLE START] (SIM-)
Code
Name/Description
Setting range
Factory settings
tCC
[2/3 wire control]
[2 wire control]
(2C)
2C
[2 wire control]
(2C)
3C
[3 wire control]
(2C)
2 wire control: This is the input state (0 or 1) or edge (0 to 1 or 1 to 0), which controls running or stopping.
Example for wiring as "source":
Ll1: Forward
Llx: Reverse
3-wire control (edge-controlled): A "forward" or "reverse" pulse is sufficient for motor startup. A "stop" pulse is sufficient to stop the motor.
Example for wiring as "source":
Ll1: Stop
Ll2: Forward
Llx: Reverse
Warning!
ACCIDENTAL OPERATION OF DEVICE
To change the assignment of
[2/3 wire control]
(tCC)
, press down on the "ENT" key for 2 s. The following function is reset to
the factory settings:
[Type 2 wire control]
(tCt)
,
see "Input and output parameters (tCC - rr5)" on page 166
, as well as all the
functions that assign the logic inputs.
The selected macro configuration will also be reset if they contain customer-specific settings (loss of customer-specific settings).
Check that this change is compatible with the wiring diagram used.
Failure to follow these instructions will result in death or serious injury.
CFG
[Macro configuration]
[Start/Stop]
(StS)
StS
[Start/Stop]
(StS)
: Operating / Standstill
HdG
[Mater.Handl]
(HdG)
: Conveyor technology
HSt
[Hoist]
(HSt)
: Hoisting gear
GEn
[Gen. Use]
(GEn)
: General applications
PId
[PID CONTROLLER]
(PId)
: PID control
nEt
[Buscom.]
(nEt)
: Communication bus
MSL
[Mast./Slave]
(MSL)
: Master / Slave
Warning!
ACCIDENTAL OPERATION OF DEVICE
To change the assignment of
[Macro config.]
(CFG)
, press down on the "ENT" key for 2 s.
Check that the selected macro configuration is compatible with the wiring diagram used.
Failure to follow these instructions will result in death or serious injury.
CCFG
[Customized macro]
Read-only parameter, only visible if at least one macro configuration parameter has been modified.
YES
[Yes]
(YES)
bFr
[Standard mot. freq]
[50 Hz IEC]
(50)
50
[50 Hz IEC]
(50)
: IEC
60
[60 Hz NEMA]
(60)
: NEMA
This parameter changes the default setting of the following parameters:
[Rated motor voltage]
(UnS)
,
[Size frequency]
(HSP)
,
[F. thresh. Mot]
(Ftd)
,
[Rated motor freq.]
(FrS)
,
[Max. output freq.]
(tFr)
,
[Rated motor current:]
(nCr)
,
[Rated motor speed]
(nSP)
and
[Brake tightening power]
(Ibr)
.
IPL
[Input phase fault]
According to in-
verter performance
nO
[Ign fault]
(nO)
: Fault ignored; to be used when the inverter is supplied via a single phase supply or by the DC bus.
YES
[freewheel stop]
(YES)
: Fault with stop in freewheel stop.
At the loss of a phase the inverter goes into the fault mode
[Line phase error]
(IPL)
. In case of a loss of 2 or 3 phases, the operation of the
inverter continues until the triggering of an undervoltage fault.
This parameter can be set in this menu only for inverters of type 8I84T200037.01P-1 to 8I84T200750.01P-1 (single-phase operation).
nPr
[Rated motor power]
According to in-
verter performance
According to in-
verter performance
Rated motor power in accordance with the nameplate in kW if
[Standard Motorfreq.]
(bFr)
=
[50 Hz IEC]
(50)
; in HP, if
[Standard Motorfreq.]
(bFr)
=
[60 Hz NEMA]
(60)
.
Содержание ACOPOSinverter P84
Страница 2: ......
Страница 384: ...Accessories 384 ACOPOSinverter P84 User s Manual 2 10 8I0FT180 300 1 A Nm lb in 8I0FT180 300 1 25 221 3...
Страница 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Страница 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Страница 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Страница 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Страница 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Страница 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...