Programming guidelines
316
ACOPOSinverter P84 User's Manual 2.10
Factory setting parameters
Code
Name/Description
FCSI
[Config. Source]
Choice of source configuration.
InI
[Use macro conf]]
(InI)
: Factory configuration; return to the selected macro configuration.
CFG1
[Config 1]
(CFG1)
CFG2
[Config 2]
(CFG2)
If the function has been configured to a configuration change,
[Config 1]
(CFG1)
and
[Config 2]
(CFG2)
can no longer be accessed.
FrY-
[PARAMETER GROUP LIST]
List of menus to be loaded
ALL
[All]
(ALL)
: All parameters
drM
[Drive config]
(drM)
: The menu
[DRIVE MENU]
without
[COMMUNICATION]
.
In menu
[DISPLAY CONFIG.]
,
[Return std name]
changes to
[No]
.
SEt
[Settings]
(SEt)
: The menu
[SETTINGS]
without the parameter
[IR-compens.]
(UFr)
,
[slip comp.]
(SLP)
and
[Therm. rated current]
(ItH)
.
MOt
[Motor parameters]
(MOt)
: Motor parameters, see list below.
The following selection options are only available if
[Selection config.]
(FCSI)
=
[Macro config.]
(InI)
:
COM
[COMMUNICATION]
(COM)
: The menu
[COMMUNICATION]
without
[Adr Scan In 1]
(nMA1)
to
[Adr Scan In 8]
(nMA8)
and with-
out
[Adr. Scan Out1]
(nCA1)
to
[Adr. Scan Out8]
(nCA8)
.
MOn
[Menu display]
(MOn)
: The menu
[SELECT DISPLAY TYPE]
dIS
[MenU Display]
(dIS)
: The menu
[DISPLAY CONFIG.]
Note:
If the factory configuration is selected and after restoring the factory setting [PARAMETER GROUP] is empty.
GFS
[Goto FACTORY SETTINGS]
It is only possible to revert to the factory settings if at least one group of parameters has previously been selected.
With the integrated display terminal:
nO
No
YES
Yes: Hold the key for 2 seconds. The parameter changes automatically to (nO) when the process is complete.
With graphics terminal: See previous page.
SCSI
[Save config]
nO
[No]
(nO)
Str0
[Config 0]
(Str0)
: Hold the ENT key for two seconds at the integrated display terminal.
Str1
[Config 1]
(Str1)
: Hold the ENT key for two seconds at the integrated display terminal.
Str2
[Config 2]
(Str2)
: Hold the ENT key for two seconds at the integrated display terminal.
The active configuration to be saved does not appear for selection. If it is, for example, the configuration
[Config 0]
(Str0)
, then only
[Config 1]
(Str1)
and
[Config 2]
(Str2)
are displayed. The parameter changes automatically to
[No]
(nO)
when the process is complete.
Содержание ACOPOSinverter P84
Страница 2: ......
Страница 384: ...Accessories 384 ACOPOSinverter P84 User s Manual 2 10 8I0FT180 300 1 A Nm lb in 8I0FT180 300 1 25 221 3...
Страница 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Страница 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Страница 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Страница 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Страница 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Страница 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...