Programming guidelines
ACOPOSinverter P84 User's Manual 2.10
283
[TRAVERSE CONTROL] (trO-)
Code
Name/Description
Setting range
Factory settings
trO-
[TRAVERSE CONTROL]
Note:
This function cannot be used with certain other functions. Follow the instructions in
see "APPLICATION FUNCT. FUn-" on page 197
trC
[Yarn control]
[No]
(nO)
nO
[No]
(nO)
: Function not active. The other parameters are then not accessible.
LI1
[LI1]
(LI1)
-
.
-
.
-
.
[...]
(...)
: See the assignment conditions
The "traverse control" cycle starts when the assigned input or bit changes to 1 and stops when it changes to 0.
trH
[Traverse freq. high]
1)
0 to 10 Hz
4 Hz
trL
[Traverse freq. low]
1)
0 to 10 Hz
4 Hz
qSH
[Quick step High]
1)
0 to
[Traverse HSP]
(trH)
0 Hz
qSL
[Quick step Low]
1)
0 to
[Traverse LSP]
(trL)
0 Hz
tUP
[Traverse ctrl. accel.]
0.1 to 999.9 s
4 s
tdn
[Traverse ctrl. decel]
0.1 to 999.9 s
4 s
tbO
[Reel time]
0 to 9999 minutes
0 minutes
Time needed to process a reel.
EbO
[End reel]
[No]
(nO)
nO
[No]
(nO)
: Function not assigned.
r2
[CONFIGURATION R2]
(r2)
dO1
[DO1]
(dO1)
: Analog output AO, which can be used as logic output. The parameter is accessible when
[CONFIGURATION AO1]
(AO1)
=
[No]
(nO)
.
The output or relay changes to state 1 when the traverse control operating time reaches the
[reel time]
(tbO)
.
SnC
[Counter wobble]
[No]
(nO)
nO
[No]
(nO)
: Function not assigned
LI1
[LI1]
(LI1)
-
.
-
.
-
.
[...]
(...)
: See the assignment conditions
Synchronization input.
To be configured on the winding inverter (slave) only.
tSY
[Sync. wobble]
[No]
(nO)
nO
[No]
(nO)
: Function not assigned.
r2
[CONFIGURATION R2]
(r2)
dO1
[DO1]
(dO1)
: Analog output AO, which can be used as logic output. The parameter is accessible when
[CONFIGURATION AO1]
(AO1)
=
[No]
(nO)
.
To be configured on the yarn guide inverter (master) only.
dtF
[Decrease ref. speed]
0 to 599 Hz
0 Hz
Decrease in the base reference during the traverse control cycle.
rtr
[Init. traverse ctrl]
[No]
(nO)
nO
[No]
(nO)
: Function not assigned.
LI1
[LI1]
(LI1)
-
.
-
.
-
.
[...]
(...)
: See the assignment conditions
In state 1 of the input or of the assigned bits, the operating time in "traverse control" mode and
[reference difference]
(dtF)
is set to zero.
1)
This parameter can also be accessed via the
[SETTINGS]
(SEt-)
menu.
Parameter that can be modified during operation or when stopped.
Содержание ACOPOSinverter P84
Страница 2: ......
Страница 384: ...Accessories 384 ACOPOSinverter P84 User s Manual 2 10 8I0FT180 300 1 A Nm lb in 8I0FT180 300 1 25 221 3...
Страница 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Страница 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Страница 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Страница 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Страница 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Страница 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...