Programming guidelines
ACOPOSinverter P84 User's Manual 2.10
193
Control parameters
Code
Name/Description
Factory settings
Fr1
[Ref.1 channel]
[AI1]
(AI1)
AI1
[AI1]
(AI1)
: Analog input
AI2
[AI2]
(AI2)
: Analog input
LCC
[HMI]
(LCC)
: Graphics terminal
Mdb
[Modbus]
(Mdb)
: Not usable
CAn
[CANopen]
(CAn)
: Integrated bus interface
nEt
[Com. Card]
(nEt)
: Communication card, if present
PG
[Encoder]
(PG)
: Encoder input, if encoder card present
rIn
[RV Inhibition]
[No]
(nO)
nO
[No]
(nO)
YES
[Yes]
(YES)
Blocking in the reverse direction, with the exception of a direction requested by logic inputs.
•
Reverse run requested by logic input is taken into account.
•
Reverse run requested by graphic display terminal is not taken into account.
•
Reverse run requested via the control is not taken into account.
•
Each inverted speed reference output from PID, from the reference summation, etc. is regarded as a zero reference (0 Hz).
PSt
[Stop Key priority]
[Yes]
(YES)
nO
[No]
(nO)
YES
[Yes]
(YES)
: Gives priority to the STOP key on the graphic display terminal when the graphic display terminal is not enabled as the command
channel.
For the recording of all changes made to an assignment of
[priority STOP]
(PSt)
, the ENT key must be pressed for two seconds.
This stop is one that stops in freewheel stop. If the active command channel is the graphic display terminal, then this stop is done in accordance
with
[STOP MODE]
(Stt)
regardless of configuration of
[priority STOP]
(PSt)
.
CHCF
[Profile]
[together]
(SIM)
SE8
[Series 8]
(SE8)
: Not applicable
SIM
[together]
(SIM)
: Reference and control command not separate.
SEP
[separate]
(SIM)
: Reference and control command are separate. The access to this assignment is not possible in the
[I/O profile]
(IO)
.
I/O
[Profile I/O]
(IO)
: I/O Profile
If
[Series 8]
(SE8)
is selected and
[Profile I/O]
(IO)
is deselected, then the return to factory setting is mandatory and is carried out automatically.
This factory setting only affects the menu
[DRIVE MENU]
without
[COMMUNICATION]
and without
[MENU PROG. CARD]
.
•
A screen for the execution of this function is shown on the graphic display terminal. Follow the instructions on the screen.
•
Hold the ENT key for two seconds at the integrated display terminal. This stores the selection and resets it to the factory setting.
1)
With the use of POWERLINK the standard setting is automatically changed to
[CANopen]
(CAN)
if the "download parameters" in the I/O configuration are
set to
[Yes]
(YES)
.
Содержание ACOPOSinverter P84
Страница 2: ......
Страница 384: ...Accessories 384 ACOPOSinverter P84 User s Manual 2 10 8I0FT180 300 1 A Nm lb in 8I0FT180 300 1 25 221 3...
Страница 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Страница 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Страница 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Страница 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Страница 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Страница 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...