10. Restart the devices that you changed. Select the
Download
button. The
Error Check
dialog box is displayed.
11. Click
OK
. The
Download Configuration
dialog box is displayed.
12. Click the check box next to each device you need to restart. Click
Start Download
.
Restarting a device may take one or five minutes.
13. Verify the status of device(s) you restarted.
a. In the Yokogawa Field Wireless Management Console, open
Monitor
.
b. In the tool bar, click the
Field Device List
button. The
Field Device List
dialog box is
displayed.
c. For each type of device, verify that the status of each type of Ranger Pro device is:
70M300 Repeater
70M301 Single Axis
70M303 Tri-Axis
Configuration Status Not Published
Published
Published
If the status is
Session Timeout
, you must resolve the timeout issue before
proceeding.
14. To verify the device status:
a. In the Yokogawa Field Wireless Management Console, open
Configurator
.
b. Select
Sampling Data
. The
Sampling Data
pane is displayed.
c. Click
Edit
. The
Sampling Settings
dialog box is displayed.
d. Verify that the firmware version, CF file version, and OID parameters are correct for
the device.
Provision Devices
To provision Ranger Pro devices on a Yokogawa ISA100 gateway:
1. In the Yokogawa Field Wireless Management Console, open
Monitor
.
2. Choose
Tools
>
OTA Provisioning Manager
.
3. To allow unprovisioned devices to join, select
Enable Provisioning Network
. Wait for
unprovisioned Ranger Pro devices to display in the
Provisioning Network
list. Wait time
may be 5 to 30 minutes and depends on the 3rd party ISA network.
4. In the
Target Device
tag field, select the device tag assigned to the device.
5. Select the devices desired and choose
Start Provisioning
.
6. Wait for all devices to be provisioned and display in the
Operating Network
List.
Depending on the number of devices and their current sleep state, provisioning may take up to
several hours. If a device fails to join the network,
see Reboot the Device on page 28.
24/56
Ranger Pro Wireless Condition Monitoring Device
User Guide
125M6113 Rev. D