UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
97 - 141
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
AOx Error Detect Enable
Access
RW
PDO Mapping
No
Value Range
0 (FALSE) or 1 (TRUE)
Default Value
1 [TRUE]
2.4.14. Object 2311h: AO Error Clear Hysteresis
This object is used to define the absolute difference that can be tolerated between the target output (as
commanded by the control input) and the measured feedback. Any difference outside of the value will flag an
open or short circuit fault. It is scaled in the physical unit of the output FV, i.e. object 6332h applies to this
object.
Object Description
Index
2311h
Name
AO Error Clear Hysteresis
Object Type
ARRAY
Data Type
INTEGER16
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
AOx Error Clear Hysteresis
Access
RW
PDO Mapping
No
Value Range
0 to 10% of 7321h or 7323h,
whichever is larger
Default Value
100 [mV]
2.4.15. Object 2312h: AO Error Reaction Delay
This object is used to filter out spurious signals and to prevent saturating the CANopen ® network with
broadcasts of object 1003h as the fault is set/cleared. Before the fault is recognized (i.e. the EMCY code is
added to the pre-defined error field list), it must remain active throughout the period of time defined in this
object. The physical unit for this object is milliseconds.
Object Description
Index
2312h
Name
AO Error Reaction Delay
Object Type
ARRAY
Data Type
UNSIGNED16