UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
71 - 141
Value Range
Default Value
40 (Voltage)
2.3.5. Object 6112h: AI Operating Mode
This object enables special operating modes for the input.
Object Description
Index
6112h
Name
AI Operating Mode
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
AIx Operating Mode
Access
RW
PDO Mapping
No
Value Range
Default Value
1 (normal mode)
2.3.6. Object 7120h: AI Input Scaling 1 FV
This object describes the field value of the first calibration point for the analog input channel, as shown in
Figure 8
. It also defines the “minimum” value of the analog input range when using this input as a control
source for another function block, as described in Table 17 in Section 1.4. It is scaled in the physical unit of
the FV, i.e. object 2102h applies to this object.
Object Description
Index
7120h
Name
AI Input Scaling 1 FV
Object Type
ARRAY
Data Type
INTEGER16
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2