UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
24 - 141
Table 13
– Object 6250h DO Fault Mode Options
1.4.
Analog Output Function Block
Figure 10
– Analog Output Objects
Together Objects 6310h
AO Output Type
and 2302h
AO Output Range
define how the output
drive circuitry will be configured. Options for object 6310h
AO Output Type
This table also shows the output unit and range for each type. By default, analog outputs are
configured as voltage outputs.
Value Meaning
0
Output Disabled
10
Output Voltage
20
Output Current
30
Output Frequency
40
Output PWM
1000
Output Digital On/Off
1001
Output Mixed PWM and Frq
Table 14
– Object 6310h AO Output Type Options