![AXIOMATIC AX130511 Скачать руководство пользователя страница 90](http://html1.mh-extra.com/html/axiomatic/ax130511/ax130511_user-manual_3037093090.webp)
UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
90 - 141
Name
DI Pullup/Down Mode 1 Input Line
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
Digital Input x Pullup/Down
Access
RW
PDO Mapping
No
Value Range
See Table 1
Default Value
0 (pullup/down disabled)
2.4.2. Object 2100h: AI Input Range
This object, in conjunction with 6110h AI Sensor Type, defines the analog input defaults (Table 9) and
allowable ranges (Table 10) for objects 2111h, 7120h, 7122h, 7148h and 7149h. The number and types of
ranges will vary according to what type of sensor is connected to the input, as described in Table 8.
Object Description
Index
2100h
Name
AI Input Range
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
Input x Range
Access
RW
PDO Mapping
No
Value Range
Default Value
1 [0-5V]
2.4.3. Object 2101h: AI Number of Pulses Per Revolution
This object is only used when a “Frequency” input type has been selected by object 6110h. The controller will
automatically convert frequency measurement from Hz to RPM when a non-zero value is specified. In this