UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
127 - 141
This object defines the input sources that will be used in the mathematical calculations. Here, y = 1 to 4
–
representing Math Block 1 to Math Block 4. If a control source is not used, the associate mathematical
calculation would be ignored. The available control sources on the 2IN-2OUT-SIG-CO controller are listed in
Table 15.
Object Description
Index
4y00h (y = 1 to 4)
Name
Math Y Input Source
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
4
Default Value
4
Sub-Index
1h to 4h (X = 1 to 4)
Description
Math Y Input X Source
Access
RW
PDO Mapping
No
Value Range
Default Value
0 (control source not used)
2.4.75. Object 4y01h: Math Y Input Number
This object defines the number of the input source that will be used in the math calculation. The available
control numbers are dependent on the source selected, as shown in Table 23. Once selected, the input value
will be used in the corresponding calculation as described in Section 1.9.
Object Description
Index
4y01h (y = 1 to 4)
Name
Math Y Input Number
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
4
Default Value
4
Sub-Index
1h to 4h (X = 1 to 4)