![AXIOMATIC AX130511 Скачать руководство пользователя страница 86](http://html1.mh-extra.com/html/axiomatic/ax130511/ax130511_user-manual_3037093086.webp)
UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
86 - 141
Name
PID Derivative Action Time
Object Type
ARRAY
Data Type
INTEGER16
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
PIDx Derivative Action Time
Access
RW
PDO Mapping
No
Value Range
0.001 [sec] to 1000.00 [sec]
Default Value
1 [ms or 0.001sec]
2.3.34. Object 7456h: PID Cycle Time
This object defines how frequently the PID loop is called. The physical unit is always seconds, as defined in
object 6458h, with the decimal digits (resolution) given in object 6459h.
Object Description
Index
7456h
Name
PID Cycle Time
Object Type
ARRAY
Data Type
INTEGER16
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
PIDx Cycle Time
Access
RW
PDO Mapping
No
Value Range
0.001 [sec] to 1000.00 [sec]
Default Value
10 [ms or 0.010sec]
2.3.35. Object 6458h: PID Physical Unit Timing
This read-
only object defines the physical unit of objects 7452h, 7454h and 7456h. It represents “seconds”
as the unit used in all cases.
Object Description
Index
6458h