UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
73 - 141
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
AIx Input Scaling 2 FV
Access
RW
PDO Mapping
No
Value Range
Default Value
4500 [mV]
2.3.9. Object 7123h: AI Input Scaling 2 PV
This object defines the process value of the second calibration point for the analog input channel, as shown
in Figure 8. It is scaled in the physical unit of the PV, i.e. object 6132h applies to this object.
Object Description
Index
7123h
Name
AI Input Scaling 2 PV
Object Type
ARRAY
Data Type
INTEGER16
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
AIx Input Scaling 2 PV
Access
RW
PDO Mapping
No
Value Range
Integer16
Default Value
4500 [same as 7122h]
2.3.10. Object 7130h: AI Input Process Value
This object represents the result of the input scaling applied per Figure 8, and gives the measured quantity
scaled in the physical unit of the process value (i.e. °C, PSI, RPM, etc) with the resolution defined in object
6132h AI Decimal Digits PV.
Object Description
Index
7130h
Name
AI Input Process Value
Object Type
ARRAY
Data Type
INTEGER16
Entry Description