UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
66 - 141
Default Value
0
Recall: A non-zero event timer for an RPDO means that it will result in a network fault
being flagged if it has not been received within this timeframe while in Operational mode.
2.2.15. TPDO Behavior
The 2IN-2OUT-SIG-CO Controller can support up to eight TPDO messages. All TPDOs on the 2IN-2OUT-
SIG-CO Controller use the similar default communication parameters, with the PDO IDs set according to the
pre-defined connection set described in DS-301. Most TPDOs do not exist, there is no RTR allowed, they use
11-bit CAN-IDs (base frame valid) and they are all time-driven. While, all have valid default mappings defined
(see below), only TPDO1 to TPDO3 are enabled by default (i.e. TPDO exists).
TPDO1 Mapping at Object 1A00h: Default ID 0x180 + Node ID
Sub-Index
Value
Object
0
2
Number of mapped application objects in PDO
1
0x71000110
Universal Input 1 Field Value
2
0x71000210
Universal Input 2 Field Value
3
0
Not used by default
4
0
Not used by default
TPDO2 Mapping at Object 1A01h: Default ID 0x280 + Node ID
Sub-Index
Value
Object
0
2
Number of mapped application objects in PDO
1
0x23700110
AO1 Output Feedback Field Value
2
0x23700210
AO2 Output Feedback Field Value
3
0
Not used by default
4
0
Not used by default
TPDO3 Mapping at Object 1A02h: Default ID 0x380 + Node ID
Sub-Index
Value
Object
0
2
Number of mapped application objects in PDO
1
0x50400120
Processor Temperature Field Value (measured)
2
0x50400220
Power Supply Field Value (measured)
3
0
Not used by default
4
0
Not used by default
TPDO4 Mapping at Object 1A03h: Default ID 0x480 + Node ID
Sub-Index
Value
Object
0
0
Number of mapped application objects in PDO
1
0
Not used by default
2
0
Not used by default
3
0
Not used by default
4
0
Not used by default