![AXIOMATIC AX130511 Скачать руководство пользователя страница 89](http://html1.mh-extra.com/html/axiomatic/ax130511/ax130511_user-manual_3037093089.webp)
UMAX130511 Version 1.00A Preliminary Documentation
– May be subject to change
89 - 141
3yz3
LTyz X-Axis Decimal Digits PV
VAR
UNSIGNED8
RW
No
3yz4
LTyz Y-Axis Decimal Digits PV
VAR
UNSIGNED8
RW
No
3yz5
LTyz Point Response
ARRAY
UNSIGNED8
RW
No
3yz6
LTyz Point X-Axis PV
ARRAY
INTEGER32
RW
No
3yz7
LTyz Point Y-Axis PV
ARRAY
INTEGER16
RW
No
3yz8
LTyz Output Y-Axis PV
VAR
INTEGER16
RO
Yes
3300
Logic Block Enable
ARRAY
BOOLEAN
RW
No
3310
Logic Block Selected Table
ARRAY
UNSIGNED8
RO
Yes
3320
Logic Output Process Value
ARRAY
INTEGER16
RO
Yes
3x01
LB(3-x) Lookup Table Number
ARRAY
UNSIGNED8
RW
No
3x02
LB(3-x) Function Logical Operator
ARRAY
UNSIGNED8
RW
No
3x11
LB(3-x) Function A Condition 1
RECORD
UNSIGNED8
RW
No
3x12
LB(3-x) Function A Condition 2
RECORD
UNSIGNED8
RW
No
3x13
LB(3-x) Function A Condition 3
RECORD
UNSIGNED8
RW
No
3x21
LB(3-x) Function B Condition 1
RECORD
UNSIGNED8
RW
No
3x22
LB(3-x) Function B Condition 2
RECORD
UNSIGNED8
RW
No
3x23
LB(3-x) Function B Condition 3
RECORD
UNSIGNED8
RW
No
3x31
LB(3-x) Function C Condition 1
RECORD
UNSIGNED8
RW
No
3x32
LB(3-x) Function C Condition 2
RECORD
UNSIGNED8
RW
No
3x33
LB(3-x) Function C Condition 3
RECORD
UNSIGNED8
RW
No
4500
Math Block Enable
ARRAY
BOOLEAN
RW
No
4521
Math Output Scaling 1 PV
ARRAY
INTEGER16
RW
No
4523
Math Output Scaling 2 PV
ARRAY
INTEGER16
RW
No
4530
Math Output Process Value
ARRAY
INTEGER16
RO
Yes
4532
Math Output Decimal Digits PV
ARRAY
UNSIGNED8
RW
No
4y00
Math Y Input Source
ARRAY
UNSIGNED8
RW
No
4y01
Math Y Input Number
ARRAY
UNSIGNED8
RW
No
4y03
Math Y Input Decimal Digits FV
ARRAY
UNSIGNED8
RW
No
4y20
Math Y Input Scaling 1 FV
ARRAY
INTEGER16
RW
No
4y22
Math Y Input Scaling 2 FV
ARRAY
INTEGER16
RW
No
4y40
Math Y Input Gain
ARRAY
INTEGER8
RW
No
4y50
Math Y Operator
ARRAY
UNSIGNED8
RW
No
5010
Constant Field Value
ARRAY
FLOAT32
RW
No
5040
Fault Detection Field Value
ARRAY
UNSIGNED16 RO
Yes
5041
Fault Detection Set Threshold
ARRAY
UNSIGNED16 RW
No
5042
Fault Detection Clear Threshold
ARRAY
UNSIGNED16 RW
No
5050
Fault Detection Enable Err Check 8 Faults
ARRAY
UNSIGNED8
RW
No
5041
Fault Detection Error Response Delay
ARRAY
UNSIGNED16 RW
No
5555
Start in Operational Mode
VAR
BOOLEAN
RW
No
Where yz = 01 to 06 (LUT 1 to 06) and x = 4 to 5(Logic 1 to 2) and y = 1 to 4 (Math 1 to 4)
2.4.1. Object 2020h: DI Pull UP/Down Mode 1 Input Line
This object determines how the state read on the input pin corresponds to the logic state, in conjunction with
application object 6002h, as defined in Section 1.1. The options for this object are listed in Table 1, and the
controller will adjust the input hardware according to what is specified.
Object Description
Index
2020h