2.4.30. Object 2391h: AO Frequency Input Number
This object defines the number of the source that will be used to control frequency of output in mixed output
mode. The available control numbers are dependent on the source selected, as shown in Table 23. Once
selected, the control represents the process value (X-Axis input) in Figure 11. Objects 2392h, 2394h should
therefore be updated to match the scaling limits defined by the control source/number, as listed in Table 17.
.
Object Description
Index
2361h
Name
AO Frequency Input Number
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
AOx Frequency Input Number
Access
RW
PDO Mapping
No
Value Range
Default Value
0 (null control source)
2.4.31. Object 2392h: AO Frequency Scaling 1 FV
This object defines the output frequency minimum value in mixed output mode.
Object Description
Index
7321h
Name
AO Frequency Scaling 1 FV
Object Type
ARRAY
Data Type
UNSIGNED16
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
2
Default Value
2
Sub-Index
1h to 2h (x = 1 to 2)
Description
AOx Frequency Scaling 1 FV
Access
RW
PDO Mapping
No