TELEPHONE HYBRID REMOTER DETAIL
| TELEPHONE HYBRID REMOTER DETAIL
50
14.11.2
Hybrid 2 section
In this section all the parameters relating to the Telephone Hybrid 2 (Hybrid 2) can be set
INPUT SOURCE:
This is the input of the Hybrid 2, i.e. what is sent (SEND) to the telephone
interlocutor. The options available are: Analog, Digital
Left
, Digital
Right
and Microphone. The
sensitivity levels of each input are shown at the side and are identified as follows.
ANALOG SENSITIVITY:
this is the sensitivity of the balanced analog input. Range of allowed
values: from -12.0 dBu to a maximum of +12.0 dBu in 0.1 dBu steps.
DIGITAL SENSITIVITY:
this is the sensitivity of the balanced AES3/EBU digital input. This
sensitivity value is identical for the Digital Left and Digital Right.
Range of allowed values: from -24.0 dBFs to a maximum of +0.0 dBFs in 0.1 dBFs steps.
MICROPHONE SENSITIVITY:
this is the sensitivity of the analog input (send) but with a higher
input sensitivity: the analog audio signal amplification values allowed, range from g +10dB to a
maximum of +50.0 dBu in 1 dB steps. A +48V phantom power supply is not available for this input.
2Wire Name:
this field is used to associate a mnemonic name to the 2Wire line, which is shown on the PhoneX front
LCD panel. To modify the name change the field and press “Return”
GSM Name:
this field is used to associate a mnemonic name to
the GSM connected line, which is shown on the PhoneX front
LCD panel.
These two “names” are important because they make it easy to
recognise which line is connected to the Telephone Hybrid 2; in fact the
POTS and GSM lines can both be used, but not at the same time.