PHONEX D1 AND PHONEX D2 GENERAL DESCRIPTION
| PHONEX D1 AND PHONEX D2 GENERAL DESCRIPTION
27
4
“GPIO” PORT
Interface with 15 pin female HD SubD connector. Determines the
PhoneX D2 logic status via the GPOut open collector, while it provides
the PhoneX D2 command via GPIn, thanks to the opto couplers
installed.
The PhoneX D2 status is also visible from the software panel on the
right section of the software:
- GPI Status
- GPO Status
As regards the
Opto Interface port pinout
see the Appendix at the end
of this manual. For the operation of each GPI and GPO see the
specific section in the next pages of this manual.
5
ANALOG OUTPUT
Analog audio output electronically balanced over XLR connector. Type
Mono. Over the connectors the outputs are:
1L = Hybrid Out -1
2R = Hybrid Out -2
6
ANALOG INPUT -A
Input of telephone Hybrid, with electronically balanced XLR
connection. This input is for the signal to be sent to the interlocutor via
the telephone line. The signal must be of the Mix-Minus type.
7
LINE-1
GSM-SET-LINE
Double RJ11 6/4 connector to connect the PSTN/POTS telephone line
to the telephone Hybrid n°2 (LINE socket) and to connect a telephone
device in parallel to the hybrid (SET) used, for example to dial the
number to call or to answer an incoming call.
The GSM connector is a connector for audio interface with external
GSM device for telephone Hybrid n°2. The pinout of this connector
cam be found in the technical appendix of this manual.
7
LINE-2
GSM-SET-LINE
Double RJ11 6/4 connector to connect the PSTN/POTS telephone line
to the telephone Hybrid n°2 (LINE socket) and to connect a telephone
device in parallel to the hybrid (SET) used, for example to dial the
number to call or to answer an incoming call.
The GSM connector is a connector for audio interface with external
GSM device for telephone Hybrid n°1. The pinout of this connector
cam be found in the technical appendix of this manual.
8
POWER SUPPLY
Switch with on/off light. The switch-power socket unit is fitted with a
fuse drawer that contains the power supply fuse and a spare one with
the same characteristics: a retarded 2000 mA for 230V mains voltage.