TELEPHONE HYBRID REMOTER DETAIL
| TELEPHONE HYBRID REMOTER DETAIL
54
14.11.4
Program Settings Section
The Program Settings section shows all the functions of the PhoneX Remoter Control Software and of the PhoneX
device.
Visualisation and Program Features
: The “Show peak meter” checkbox offers the possibility to see the peak meter on
the levels section of the two Hybrids.
Setup Password:
This field is used to enter an alphanumeric Password of maximum 8
digits, which is required to access the device Setup section. Enter the password and click
Return. This password must be entered in the User Authentication box to access the
Setup section. If you forget the password the device must be returned to the
manufacturer in order to be used again. There are no backdoors and Axel Technology’s
Technical Assistance Service is not authorised
to instruct others to tamper with the device.
Information & Connection Information :
This panel
provides a summary of the PhoneX model in use, the name
of the device, the firmware version installed on the DSP of
the device and the univocal firmware code assigned to
each single device. The Copy Firmware code to Clipboard
key is used to save the Firmware code in the notebook, so
that this alphanumeric code can be sent to Axel
technology to execute Upgrades or improve the product.
The Connection Information box shows the type of
connection in use. It can be Serial or TCP/IP, and the IP and Port values are also shown.
Country Line Setup:
Select the country in which PhoneX is installed from this list. This
parameter is important for the configuration of the impedance set inside the PhoneX, which
will change and adapt the input telephone line with the line provided in the country in which
PhoneX is installed.
UNDO:
press UNDO to reset the values set in the whole Hybrid 1, Hybrid 2 and Outputs
section to the values set on the device before the opening of the control panel. The
Disconnect key disconnects the device from the control software.