System Components: Physical Ports
13.13.5 BRI Port (To)
These ports are BRI To interface ports for connection to external BRI trunk services. Note that BRI ports found on the
IP500 So8 module are BRI-S interface ports for connect to ISDN terminal devices, see
BRI Port (So)
.
PRI/BRI Trunk Cable
This cable is used to connect from IP Office BRI/PRI trunk ports to the line providers network termination equipment. If
that equipment does not use RJ45 sockets, the cable may need to be stripped and rewired or an alternate cable used.
The appropriate signal pin-outs and wire colours are detailed below.
IP Office
Wire
Network
Termination
BRI
RJ45
BRI
PRI
PIN
RJ45
1
–
Rx-A
White/Orange
1
2
–
Rx-B
Orange/White
2
3
Tx-A
–
White/Green
3
4
Rx-A
Tx-A
Blue/White
4
5
Rx-B
Tx-B
White/Blue
5
6
Tx-B
–
Green/White
6
7
–
–
White/Brown
7
8
–
–
Brown/White
8
·
Supply: BRI/PRI trunks cards are not supplied with these cables.
·
Cable Color: Red.
·
SAP Code: 700213440.
·
Standard Length: 3m/9'10".
·
Maximum Length: 5m/16'5''.
·
Though not used pins 7 and 8 are through connected for ease of construction.