7. Product Specifications and I/O Signal Connection
63
© Copyright Reserved Autonics Co., Ltd.
●
Description 3
:
STROBE Pin3(Input drive start command)
The STROBE Pin3 is the start command signal in Index mode and Program mode.
If you make this signal in ON state after specifying a register number and X/Y axis, the
drive starts. Make the STROBE signal in the ON state of more than 80 msec or check if
the nDRIVE/END signal is in the ON state. After then, return the signal in the OFF state.
However, if the nDrive/END signal is used as the drive end pulse, make the STROBE
signal in the ON state of 80 msec.
●
Description 4
:
X/SCANY+ Pin4(Input, X-axis specification/Y+ in Scan drive mode)
Y/SCANY- Pin5(Input, Y-axis specification/Y- in Scan drive mode)
This signal specifies an axis in the Index mode and the Program mode. If the specified axis
goes to the ON state, the relevant axis is selected. Before the STROBE signal is in the ON
state, the axis specification signal must be in the ON state.
In the Scan drive 2 mode, if SCANY+ and SCANY- are changed to the ON state, the drive
pulse comes out in the Y+ and Y- directions respectively.
●
Description 5
:
REGSL0/RUN+/SCANX+ Pin6(Input, Register specification0/RUN+/X+ in Scan drive mode)
REGSL1/RUN-/SCANX- Pin7(Input, Register specification1/RUN-/X- in Scan drive mode)
REGSL2/SPD0 Pin8(Input, Register specification2/Drive speed specification0)
REGSL3/SPD1 Pin9(Input, Register specification3/ Drive speed specification1)
REGSL4/SCAN Pin10(Input, Register specification4/Scan specification0)
REGSL5/STOP Pin11(Input, Register specification5/ Drive stop)
These signals specify REG numbers in the Index mode and the Program mode.
REGSL0 and REGSL5 are LSB and HSB respectively, and the signals specify REG num
-
bers 0~63. RUN+ and RUN- are separately used in the Scan drive1 and Continuous mode
respectively. In addition, when RUN- is in the ON state, the drive pulse comes out in the
-direction. At this time, the drive speed is configured as SPD0 and SPD1.
< Drive speed specifcation >
Drive Speed
SPD1
SPD0
Drive Speed 1
OFF
OFF
Drive Speed 2
OFF
ON
Drive Speed 3
ON
OFF
Drive Speed 4
ON
ON
If SCANX+ and SCANX- are in the ON state in the Scan drive2 mode, the drive pulse
comes out in the X+, Y- direction respectively. The STOP signal is the drive stop signal,
if the signal enters to the ON state, the drive stops. The signal has different functions
depending on the operational mode as listed in the table below.
In addition, the signal operates in the ON state of 80 msec to operate.
Operation mode
Operation of the Stop Signal in the ON state.
Index drive
Stop the running drive of the ABS or the INC command.(See Caution)
Scan Drive 1, 2
Disable
Continuous Drive Stop the continuous drive.
Program Drive
Stop the program drive.
Stop the drive, if a drive command is running.(See Caution)
Home Search
Stop during the executing of home search.
Содержание PMC-1 HS
Страница 29: ...3 Configuration of the Operating Mode and System Parameters 26 Copyright Reserved Autonics Co Ltd ...
Страница 39: ...4 Configuration of Operation Program 36 Copyright Reserved Autonics Co Ltd ...
Страница 61: ...6 Drive by Teaching Unit 58 Copyright Reserved Autonics Co Ltd ...
Страница 82: ...turkey autonics com DRW170814AB ...