4. Configuration of Operation Program
35
© Copyright Reserved Autonics Co., Ltd.
4.5
Continuous Drive
The continuous drive outputs drive pulses in + direction when the input signal RUN+(6) is in ON state or
in - direction when the input signal RUN-(7) is in ON state. It outputs the drive pulse until the stop sig-
nal STOP(11) goes to the ON state, in other words, the RUN signal of the drive is changed into the Stop
signal(If the Limit input in the proceeding direction is activated, the output stops).
The drive speed is configured as one of four drive speeds(from drive speed1~4) by the input signal SPD0
and 1(8, 9). If the configuration of the drive speed is changed in driving, the speed is changed into the
changed speed at once.
Item specified
Input signal of CN3
Operation mode specification : Continuous mode MODE0(12) = OFF, MODE1(13) = ON
Axis specification
X(4), Y(5) = On state of the axis to execute
Drive speed specification
Refer to drive speed configuration for SPD0(8) ~ SPD1(9)
4.6
Program Drive
The program drive executes the operation program registered. The program drive is started by configur
-
ing the following items as the input signal of parallel P I/F connector(CN3) when the drive start command,
STOBE(3) is in ON state.
Item specified
Input signal configuration to CN3
Operation mode : Index mode
MODE0(12) = ON, MODE1(13) = ON
Axis specification
X(4), Y(5) = ON state of the axis to execute
Register number specification
Refer to "Register number specification table
in chapter 4.3" for REGSL(6) ~ REGSL5(11).