4. Configuration of Operation Program
31
© Copyright Reserved Autonics Co., Ltd.
END End program
CMD
Data
END
-
End the program. This command must be written the end of the program.
TIM Timer
CMD
Data
TIM
Waiting time(msec)
Be on standby until specified time.
lData : Specifies time in msec unit. The range is 0~65535 msec.
NOP
CMD
Data
NOP
-
Not operated.
4.1.2
I/O port numbers
Input port numbers
Input port No
Connector
Pin No
Signal name Signal description
Signal type
0
CN4
11
XSTOP0
Near home
X-axis signal
1
CN4
10
XSTOP1
Home
2
CN4
9
XSTOP2
Encoder Z-phase
3
CN4
6
XINPOS
Servo inposition
10
CN5
11
YSTOP0
Near home
X-axis signal
11
CN5
10
YSTOP1
Home
12
CN5
9
YSTOP2
Encoder Z-phase
13
CN5
6
YINPOS
Servo inposition
20
CN3
6
REGSL0
REGSL signal
Parallel
P I/F signal
21
CN3
7
REGSL1
22
CN3
8
REGSL2
23
CN3
9
REGSL3
24
CN3
10
REGSL4
PHC-1HS can not use input port 10~13.
Output numbers
Output port No
Connector
Pin No
Signal name
Signal description
Signal type
0
CN4
5
XOUP0
General output X-axis 0
X-axis signal
10
CN5
5
YOUT0
General output Y-axis 0
Y-axis signal
PHC-1HS can not use input port 10.