Audi Q7 2007
!
6-cylinder TDI engine (3.0 ltr. 4-valve common rail), mechanics 01.2006
1 Servicing charge air system with turbocharger
197
6
1.4
Removing and installing intermediate
flange
Removing
–
Remove starter catalytic converter
⇒
page 204
.
–
Remove turbocharger
⇒
page 195
.
–
Unscrew bolts -arrows- and detach intermediate flange
with connecting pipe for exhaust gas recirculation.
Installing
Installation is carried out in the reverse order; note the follow-
ing:
Renew seals and gaskets.
–
Tighten bolts securing intermediate pipe to intermediate
flange as follows:
1. Tighten with torque wrench initially to 10 Nm.
2. Tighten with torque wrench to 30 Nm.
3. Turn 90
°
(
1
/
4
turn) further using a rigid wrench.
–
Install turbocharger
⇒
page 195
.
–
Install starter catalytic converter
⇒
page 204
.
Tightening torques
Component
Nm
Turbocharger to:
intermediate
flange
25
1)
engine
22
Oil return line to:
turbocharger
9
cylinder block
9
Oil supply pipe to turbocharger
15
•
1)
Coat with high-temperature paste; refer to
⇒
Parts
catalogue.
Component
Nm
EGR connect-
ing pipe to:
intermediate flange
9
1)
change-over flap for ex-
haust gas recirculation
cooler
25
Intermediate pipe to intermediate flange
30
1)2)3)
•
1)
Renew bolts.
•
2)
90
°
= one quarter turn.
•
3)
Coat with high-temperature paste; refer to
⇒
Parts
catalogue.
Note