Audi Q7 2007
!
6-cylinder TDI engine (3.0 ltr. 4-valve common rail), mechanics 01.2006
Repair Group 19 – Cooling
6
170
Removing
–
Unscrew bolts and remove front noise insulation -1-.
–
Unplug electrical connector -1- at continued coolant circu-
lation pump -V51-.
–
Clamp off hoses -3- and -4- using hose clamps -3094- and
detach from continued coolant circulation pump -V51-.
–
Unscrew bolt -2- and remove continued coolant circulation
pump -V51-.
Installing
Installation is carried out in the reverse order; note the follow-
ing:
Secure all hose connections with the correct type of hose
clips (same as original equipment)
⇒
Parts catalogue.
–
Check coolant level
⇒
page 166
.
Tightening torques
Component
Nm
Bracket for continued coolant circulation
pump -V51- to longitudinal member
22
Note