
Audi Q7 2007
!
6-cylinder TDI engine (3.0 ltr. 4-valve common rail), mechanics 01.2006
Repair Group 19 – Cooling
6
172
–
Install poly V-belt
⇒
page 39
.
–
Fill cooling system
⇒
page 162
.
Tightening torque
1.7
Removing and installing coolant tempera-
ture sender -G62-
Removing
–
Drain off coolant
⇒
page 161
.
–
Carefully pull engine cover panel off four retaining pins one
after the other -arrows-.
–
Remove air intake hose -arrows-.
–
Unplug electrical connector -1- at coolant temperature
sender -G62-.
–
Detach retaining clip -2- and remove coolant temperature
sender -G62-.
Installing
Installation is carried out in the reverse order; note the follow-
ing:
♦
Renew O-ring.
♦
Secure all hose connections with the correct type of hose
clips (same as original equipment)
⇒
Parts catalogue.
–
Fill cooling system
⇒
page 162
.
Component
Nm
Hose connection with thermostat to engine
9
Note
更多资料请访问深度汽车论坛 http://shenduauto.com/ 客服QQ:1398556747 电话:18218750259