72
Operation
Detail parameter description
Date and time
DHW preheating
Date and time
The control unit is equipped with a
365-day clock that displays day, month,
year and time. To ensure correct boiler
operation when using time programs,
the date and time must be set correctly.
If the boiler is connected to the App via
Wifi, the Internet time is automatically
taken over.
Hot water preheating function
(comfort function)
This parameter allows the end user
to select the hot water comfort. The
higher the comfort, the higher the
energy consumption.
- OFF: The boiler starts to heat the
hot water only in the case of a tap
- TIME: after each tapping, the boiler
maintains the comfort temperature
for 30 minutes
- ON: Boiler keeps hot water 365
/ 24h at the desired comfort
temperature.
Time program Comfort function
DHW
Five different pre-defined time
programs are available for DHW
heating. These programmes are
0-24h
Mo-So
00:00 – 24:00
P1
Family program
Mo-Do
06:00 – 22:00
Fr-Sa
06:00 – 23:00
So
07:00 – 22:00
P2
Program without
noon
Mo-Do
06:00 – 08:00 16:00 – 22:00
Fr
06:00 – 08:00 15:00 – 23:00
Sa
07:00 – 23:00
So
08:00 – 22:00
P3
Program with lunch
Mo-Do
06:00 – 08:00 11:30 – 13:00 16:00 – 22:00
Fr
06:00 – 08:00 11:30 – 23:00
Sa
06:00 – 23:00
So
07:00 – 22:00
6-22h
Mo-Do
06:00 – 22:00
activated when DHW preheating is set
to “TIME”. The programs control the
DHW set point for the various switching
times. Outside these time windows, hot
water preheating is deactivated.