User Manual
54
KDC Series II DC Power Supplies
4.6 Mode Status
The KDC Series can operate in one of two modes of operation, voltage mode or current mode
with automatic cross over.
Mode
Description
Voltage Mode (CV) mode
Constant voltage mode. The supply maintains
the set voltage. If the current limit is exceeded,
the output trips off.
Constant Current (CC) mode
Constant current mode. The supply maintains
the set voltage as long as the load current is
below the set current limit. If the current limit is
exceeded, the output voltage is reduced to
maintain the set current level. If the load
currents falls below the set current limit, the
output voltage returns to its set value.
Constant Power (CP) mode
Constant power mode. The supply maintains the
set voltage as long as the power level is below
the set power level. If the power reaches the set
level, the voltage is reduced as needed to
maintain the set power level.
Note: This mode requires firmware revision 1.11 or
higher.
Table 4-6: Operating Modes
The currently active mode is always indicated by the CV, CC and CP status LED's on the front
panel and may also be queried through he remote control interface. Note that when transitioning
between states, both or neither LED may be on due to some hysteresis in the circuitry.
Содержание KDC 100-100
Страница 2: ......
Страница 10: ......
Страница 26: ...User Manual 16 KDC Series II DC Power Supplies Figure 3 1 Location of rear panel connectors ...
Страница 33: ...User Manual KDC Series II DC Power Supplies 23 Figure 4 3 Front panel layout ...
Страница 82: ......
Страница 83: ...User Manual KDC Series II DC Power Supplies 73 Figure 6 1 DC Power Supply Block Diagram ...
Страница 84: ...User Manual 74 KDC Series II DC Power Supplies Figure 6 2 DC Power Supply Block Diagram with IF option ...
Страница 111: ...User Manual KDC Series II DC Power Supplies 101 Figure 8 2 Replaceable Fuse Locations ...