KDC Series II DC Power Supplies
11.3.4 AMD Option Test Tables
Test
No.
Section
Subject
Test Limits
Comment
File Ref.
LDC101
Steady State Voltage
32 to 24 Volts RMS
DO160 16.6.1.1.b
LDC101
LDC101
APU
Steady State Voltage
32.5 to 23.5 Volts RMS
DO160 16.6.1.1.b
LDC101-APU
LDC102
Voltage Transients
Surge to 36V max, Sag to 18.5V min
Per Table LDC 102-1
LDC102
LDC102
APU
Voltage Transients
Surge to 40V max, Sag to 17V min
Per Table LDC 102-APU
LDC102-APU
LDC103
Voltage Ripple
Maximum 5kHz ripple.
Requires Additional Equipment
LDC103
APU
Voltage Ripple
Maximum 5kHz ripple.
Requires Additional Equipment
LDC104
Voltage Spikes
Requires Additional Equipment
LDC105
Inrush Current
Test requires multiple load cables
Requires Additional Equipment
LDC105
APU
Inrush Current
Test requires multiple load cables
Requires Additional Equipment
LDC106
Voltage Variations Due to APU Starting
Start at 12.5V, ramp up to 26.5V
Per Figure 13, Appendix B
LDC106
LDC107
DC Ripple Voltage Due to Equipment
Requires Additional Equipment
LDC108
Voltage Spike due to Equipment Load Switching
Requires Additional Equipment
LDC109
Compatibility with SEPDC Voltage Clipping
Devices
Requires Additional Equipment
LDC201
Abnormal Voltage Transients
36 to 0 Volts
DO160 16.6.2.4.c and 16.6.2.3.b
LDC201
LDC201
APU
Abnormal Voltage Transients
46 to 0 Volts
DO160 16.6.2.4.c and 16.6.2.3.b
LDC201-APU
LDC301
Emergency Steady State Voltage
32 to 18.5 Volts
DO160 16.6.1.1.b
LDC301
LDC302
Emergency Voltage Ripple
Maximum 5kHz ripple.
Requires Additional Equipment
LDC303
Emergency Inrush Current
Test requires special cables
Requires Additional Equipment
LDC401
Transparency Time
3ms dropouts
Per Figure LDC 401-1
LDC401
LDC401
APU
Transparency Time
10ms dropouts
Per Figure LDC 401-1
LDC401-APU
LDC402
Voltage Switching Transients 1
Test Conditions 1-18
Per Figure LDC 402-1
LDC402
LDC402
APU
Voltage Switching Transients 1
Test Conditions 1-17
Per Figure LDC 402-APU
LDC402-APU1
LDC402
APU
Voltage Switching Transients 1
Test Conditions 18-27
Per Figure LDC 402-APU
LDC402-APU2
LDC402
APU
Voltage Switching Transients 1
Test Conditions 28-36
Per Figure LDC 402-APU
LDC402-APU3
LDC402
APU
Voltage Switching Transients 1
Test Conditions 37-42
Per Figure LDC 402-APU
LDC402-APU4
LDC403
Voltage Switching Transients 2
T=1 to T=100
Per Figure LDC 403-1
LDC403
LDC403
APU
Voltage Switching Transients 2
T=1 to T=49
Per Figure LDC 403-APU
LDC403-APU1
Содержание KDC 100-100
Страница 2: ......
Страница 10: ......
Страница 26: ...User Manual 16 KDC Series II DC Power Supplies Figure 3 1 Location of rear panel connectors ...
Страница 33: ...User Manual KDC Series II DC Power Supplies 23 Figure 4 3 Front panel layout ...
Страница 82: ......
Страница 83: ...User Manual KDC Series II DC Power Supplies 73 Figure 6 1 DC Power Supply Block Diagram ...
Страница 84: ...User Manual 74 KDC Series II DC Power Supplies Figure 6 2 DC Power Supply Block Diagram with IF option ...
Страница 111: ...User Manual KDC Series II DC Power Supplies 101 Figure 8 2 Replaceable Fuse Locations ...