User Manual
KDC Series II DC Power Supplies
35
4.2.5
Measurement Menu
The measurement menu is used only for display purposes. There are no user settable fields in
this screen. The measurement screen displays all four available measurements.
The measurement menu can also be reached by pressing the MEAS key.
ENTRY
DESCRIPTION
VOLTAGE
Upper left corner field is used to display the output voltage at
the load terminals or the external sense connection. If the
output state is off, this reading will be close to zero, regardless
of the programmed voltage settings.
If the power supply is operating in the constant current or
constant power mode (CC or CP), the measured voltage may
be less than the programmed (set) voltage.
CURRENT
Upper right corner field is used to display the average dc load
current. If the output state is off or there is no load connected
to the dc supply, this reading will be close to zero, regardless
of the programmed current settings.
If the power supply is operating in the constant voltage or
constant power mode (CV or CP), the measured current may
be less than the programmed (set) current.
POWER
The lower left corner is used to display the load power
dissipation in W (Watt) or KW.
PEAK CURRENT
The lower right corner is used to display the peak current. This
is the maximum dc current level captured for any given
acquisition window. For non-transient load conditions, the peak
current reading will be close to the average dc current reading.
If the load is transient in nature, the peak current can be
significantly higher.
As of revision 2.06 firmware, the display shows a peak-hold
value of the peak current so updates will only occur if a higher
value is measured. The peak-hold can be reset by positioning
the cursor on the lower line and pressing the BACK key. This
makes it easier to determine inrush current.
Содержание KDC 100-100
Страница 2: ......
Страница 10: ......
Страница 26: ...User Manual 16 KDC Series II DC Power Supplies Figure 3 1 Location of rear panel connectors ...
Страница 33: ...User Manual KDC Series II DC Power Supplies 23 Figure 4 3 Front panel layout ...
Страница 82: ......
Страница 83: ...User Manual KDC Series II DC Power Supplies 73 Figure 6 1 DC Power Supply Block Diagram ...
Страница 84: ...User Manual 74 KDC Series II DC Power Supplies Figure 6 2 DC Power Supply Block Diagram with IF option ...
Страница 111: ...User Manual KDC Series II DC Power Supplies 101 Figure 8 2 Replaceable Fuse Locations ...