Pin out:
1. Ground from VCU
2. Temperature signal output
3. Power from VCU
4. Pressure signal output
DIAGNOSTICS INSTRUMENT: ELECTRICAL ERRORS
VCU ERRORS
Pressure sensor short circuit error C1407
Error cause
•
Excessive voltage or null voltage found from VCU PIN A3 to sensor PIN 4.
Troubleshooting
•
Disconnect the sensor connector and check PIN 4 ground and power insulation. if insulation
is not present, restore the cable harness; otherwise replace the sensor.
•
Check that sensor connector PIN 4 is insulated from both ground (connector PIN 1) and
power (connector PIN 3) and also from connector PIN 2. Reconnect the VCU, turn the key
ON and check that there are 5V between connector PIN 1 and 3. If the checks return positive
results replace the sensor.
Recovery
•
Constant current on the fork.
Pressure sensor open error C1408
Error cause
•
Circuit interruption detected.
Troubleshooting
•
Check the component connector and the VCU connector. Disconnect the two connectors
and check for continuity of the cable between sensor PIN 4 and VCU PIN A3 and restore
the cable harness. If the cable harness is intact replace the sensor.
•
Check the continuity between sensor connector PIN 1 and VCU PIN F3. Check the continuity
between sensor connector PIN 4 and VCU PIN A3. Reconnect the VCU, turn the key ON
and check that there are 5 v between connector PIN 1 and 3. If the checks return positive
results replace the sensor.
Recovery
•
Constant current on the fork
Temperature sensor short circuit error C1409
Error cause
Caponord 1200 - Caponord 1200 Rally
Electrical system
ELE SYS - 245
Содержание Caponord 1200 2016
Страница 1: ...MANUALE STAZIONE DI SERVIZIO 2Q000020 Caponord 1200 Caponord 1200 Rally ...
Страница 6: ......
Страница 7: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Страница 65: ...See also Removing the flywheel cover Caponord 1200 Caponord 1200 Rally Characteristics CHAR 65 ...
Страница 66: ...INDEX OF TOPICS SPECIAL TOOLS S TOOLS ...
Страница 73: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Страница 85: ...INDEX OF TOPICS TROUBLESHOOTING TROUBL ...
Страница 90: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Страница 103: ... Large plastic clamps 4 5x280 mm 0 18x11 02 in Caponord 1200 Caponord 1200 Rally Electrical system ELE SYS 103 ...
Страница 134: ...key 1 MULTIPLE CONNECTORS Electrical system Caponord 1200 Caponord 1200 Rally ELE SYS 134 ...
Страница 138: ...key 1 MULTIPLE CONNECTORS Electrical system Caponord 1200 Caponord 1200 Rally ELE SYS 138 ...
Страница 268: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Страница 283: ...See also Vehicle preparation Adjusting Caponord 1200 Caponord 1200 Rally Engine from vehicle ENG VE 283 ...
Страница 284: ...INDEX OF TOPICS ENGINE ENG ...
Страница 371: ...INDEX OF TOPICS POWER SUPPLY P SUPP ...
Страница 374: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Страница 417: ...INDEX OF TOPICS CHASSIS CHAS ...
Страница 451: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Страница 480: ...INDEX OF TOPICS CLUTCH SYSTEM CLU SYS ...
Страница 483: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS ...
Страница 492: ...INDEX OF TOPICS BODYWORK BODYW ...
Страница 548: ... Remove the relay box Cut and remove the clamp Bodywork Caponord 1200 Caponord 1200 Rally BODYW 548 ...
Страница 549: ... Remove the inside fairing Caponord 1200 Caponord 1200 Rally Bodywork BODYW 549 ...
Страница 550: ...INDEX OF TOPICS ...
Страница 551: ...PRE DELIVERY PRE DE ...
Страница 573: ...Tyres 17 U Use 460 W Warning lights Water pump 488 Wiring diagram 133 ...