6-2-25.
Set Scan Interval in Continueous Scan Mode
This feature allows you to specify the time interval between two consecutive scans of the
same barcode. However, to have the configurable parameter take effect, you are required to
set Scan Mode to be
Continue
, which enables scan light to stay on for a specified period of
time to continuously scan plenty of barcodes without interruption.
Procedure
(1)
Scan
Enter
barcode.
(2)
Scan
BarGoodRdTime
barcode to configure the length of the timeout session.
(3)
Please refer to Decimal/Hexadecimal Table in the appendix to scan decimal value
barcodes representing the desired decimal value in the range of 0 to 255. For
instance, to set timeout period to 0.1 second, scan
1
first and then
0
to assign the
specified decimal value “10”.
(4)
Scan
SET
barcode to complete the variable-binding operation.
(5)
Scan
End
barcode to complete the configuration.
6-2-26.
Set Header Information
Header information refers to additional messages preceding to data output while the
scanned barcodes are sent out in Memory mode. This special parameter allows you to
customize your own custom header to add clarity of transmitted data.
*A70E6*
Header
A70E6
(Length: 12 digits)
(Length: 1 digit / Range: 0-255/ Unit: 10ms)
*A5AE0*
BarGoodRdTime
A5AE0